FREE NZ SHIPPING on all orders over $100 NZD

Hunter Dual decoder for I-CORE
Hunter Dual decoder for I-CORE
Hunter Dual decoder for I-CORE
Hunter Dual decoder for I-CORE
Hunter Dual decoder for I-CORE
Hunter Dual decoder for I-CORE
Hunter Dual decoder for I-CORE
  • Load image into Gallery viewer, Hunter Dual decoder for I-CORE
  • Load image into Gallery viewer, Hunter Dual decoder for I-CORE
  • Load image into Gallery viewer, Hunter Dual decoder for I-CORE
  • Load image into Gallery viewer, Hunter Dual decoder for I-CORE
  • Load image into Gallery viewer, Hunter Dual decoder for I-CORE
  • Load image into Gallery viewer, Hunter Dual decoder for I-CORE
  • Load image into Gallery viewer, Hunter Dual decoder for I-CORE

Hunter Dual decoder for I-CORE

Regular price
$1,300.53
Sale price
$1,300.53
Regular price
Sold out
Unit price
per 
Shipping calculated at checkout.

DUAL is Hunter’s innovative two-wire plug-in for the I-Core controller. Designed to bring the convenience and efficiency of two-wire technology to all, the DUAL system can operate up to 48 zones via a single pair of wires, at distances up to 2.3 km. The 48 zones can all be installed on a single path, or divided over multiple paths to take advantage of pipe trenches. Because it only requires two wires, DUAL offers unmatchable savings in labor, wire, and money. Since it’s I-Core compatible, system operators still receive advanced features and benefits like flow monitoring, quick system overview access, a factory-installed SmartPort®, six language capability, and a bold, graphic display. Dual decoders come in one and two-station versions. Aptly named Dual-1 and Dual-2, the decoder choices ensure any I-Core Dual system is customizable to the needs of any installation.

FEATURES
  • Two-wire decoder system for I-Core controllers

  • Decoder station sizes available: 1, 2

  • Field programmable decoders (no serial numbers to enter)

  • DUAL-S external surge protection

  • DUAL decoder module display and push button programming makes it easy to program decoders at the controller itself

  • Decoder module displays decoder operation and diagnostic information

  • Can operate up to 48 stations of combined decoder and conventional control making system retrofit easy

  • Waterproof connectors for connection to two-wire path included with all DUAL decoders and DUAL-S surge protection

  • Number of 2-wire paths: 3

  • Solenoid finder feature assists in locating valves in the field.

ADVANCED FEATURES


PROGRAMMABLE DECODERS

Field programmability means no lengthy serial numbers to enter in the controller, and no time lost re-programming decoder assignments after a controller change. Each decoder is programmed with its actual station (valve) numbers for simplicity and reliability. Decoders may be re-programmed at any time if desired.

WIRELESS PROGRAMMING WITH ICD-HP

All Hunter decoders feature wireless programming and diagnostic access from the ICD-HP handheld programmer. Patented technology allows programming and diagnostics through the housing of the decoder, without removing a single wire or waterproof connector. Program, operate, and diagnose decoders in-place in field valve boxes.

COLOUR-CODED ID WIRE

Hunter’s unique jacketed decoder wire is high-strength, durable, sunlight protected, and part of the integrated lightning management system. Twisted pair conductors are color-coded for decoder system connections, and the outer jackets can be uniquely color-coded to organize field wire runs and assist in future wire tracking. Tough PE (polyethylene) jacket protects wire from sharp rocks and exposure to UV rays. Available in two wire sizes for different length requirements.

WATERPROOF CONNECTORS INCLUDED

Each Hunter decoder includes 2 DBRY-6 waterproof connector kits, UL listed to 600V direct burial. Only the best connectors will do in the critical two-wire path, but there is no need to go shopping for them separately. Suitable for all sizes of ID Wire connections.

Dual Model Specifications

  • Decoder station sizes available: 1, 2
  • Max. distance to decoder
    • 2mm2 (14 AWG) wire path: 1500 m
    • 3.3 mm2 (12 AWG) wire path: 2300 m
  • Max. recommended distance, decoder to solenoid: 30 m
  • Field programmable:
    • Dual decoder module display and push button programming makes it easy to program decoders at the controller itself
    • Dual decoders can also be field programmed with the Hunter ICD-HP. No need to remove decoders from the two-wire path
  • Decoder module displays decoder operation and diagnostic information including current draw in milliamps
  • Can operate up to 48 stations of combined decoder and conventional control making system retrofit easy
  • Dual-S external surge protectors (add in-line every 12th decoder or 1000 ft/300 m, minimum).
  • Waterproof connectors for connection to two-wire path supplied with all Dual decoders and Dual-S surge protection
  • Number of two-wire paths: 3

DUAL MODEL CHART

Base model Plus Description

IC-600-PL

DUAL48M 48-Station controller, indoor/outdoor, plastic cabinet
IC-601-PL DUAL48M International version, 48-Station controller, indoor/outdoor, plastic cabinet
IC-600-M DUAL48M 48-Station controller, indoor/outdoor, metal cabinet
IC-600-PP DUAL48M 48-Station controller, indoor/outdoor, plastic pedestal
IC-600-SS DUAL48M 48-Station controller, indoor/outdoor, stainless steel cabinet
Dual Model Description
DUAL48M DUAL decoder output module. Plug-in module converts any I-CORE
controller to 2-wire decoder system (up to 48 stations maximum)
DUAL-1 DUAL 1-station decoder (includes 2 DBRY-6 connectors)
DUAL-2 DUAL 2-station decoder (includes 2 DBRY-6 connectors)
DUAL-S DUAL surge arrestor (includes 4 DBRY-6 connectors)